1. INTRODUCTION
1.1 The
American Society of Home Inspectors®, Inc. (ASHI®) is a
not-for-profit professional society established in 1976.
Membership in ASHI is voluntary and its members include
private, fee-paid home inspectors.
ASHI's objectives include promotion of excellence within
the profession and continual improvement of its members'
inspection services to the public.
2. PURPOSE AND SCOPE
2.1 The
purpose of these Standards of Practice is to establish
a minimum and uniform standard for private, fee-paid home
inspectors who are members of the American Society of Home
Inspectors. Home Inspections performed
to these Standards of Practice are intended to provide
the client with information regarding the condition of
the systems and components of
the home as inspected at the time of the Home Inspection.
- provide
the client with a better understanding of the property
conditions, as observed at the time of the inspection.
- readily
accessible systems and components of
homes listed in these Standards of Practice.
- installed systems
and components of homes listed in these Standards of
Practice.
B.
report:
- on
those systems and components inspected
which, in the professional opinion of the inspector,
are significantly deficient or
are near the end of their service lives.
- A
reason why, if not self-evident, the system or component
is significantly deficient or near the end of
its service life.
- the
inspector's recommendations to correct or monitor the
reported deficiency.
- on
any systems and components designated for inspection
in these Standards of Practice which were present at
the time of the Home Inspection but
were not inspected and the reason they were not inspected.
2.3
These Standards are not intended to limit inspectors from:
A. including
other inspection services, systems or components in
addition to those required by these Standards of Practice.
B. specifying repairs, provided the inspector
is appropriately qualified and willing to do so.
C. excluding systems and
components from the inspection
if requested by the client.
3. STRUCTURAL COMPONENTS
3.1
The inspector shall:
A. inspect:
- the structural
components including foundation and
framing.
- by
probing a representative number of structural
components where deterioration is suspected or where
clear indications of possible deterioration exist. Probing
is NOT required when probing would damage any finished
surface or where no deterioration is visible.
B:
describe:
- the
foundation and report the
methods used to inspect the under-floor crawl space.
- the
floor structure.
- the
wall structure.
- the
ceiling structure.
- the
roof structure and report the methods used to inspect the
attic.
3.2
The inspector is NOT required to:
A. provide any engineering service or architectural
service.
B. offer an opinion as to the adequacy of any structural system or component.
4.
EXTERIOR
4.1
The inspector shall:
A. inspect:
- the
exterior wall covering, flashing and trim.
- all
exterior doors.
- attached
decks, balconies, stoops, steps, porches, and their associated
railings.
- the
eaves, soffits, and fascias where accessible from the
ground level.
- the
vegetation, grading, surface drainage, and retaining
walls on the property when any of these are likely to
adversely affect the building. walkways, patios, and
driveways leading to dwelling entrances.
- describe the
exterior wall covering.
4.2 The inspector is
NOT required to:
A. inspect:
- screening,
shutters, awnings, and similar seasonal accessories.
- fences.
- Geological,
geotechnical, or hydrological conditions.
- recreational
facilities.
- outbuildings.
- seawalls,
break-walls, and docks.
- erosion
control and earth stabilization measures.
5.
ROOFING SYSTEM
5.1
The inspector shall:
A. inspect:
- the
roof covering.
- the roof
drainage systems.
- the
flashings.
- the
skylights, chimneys, and roof penetrations.
- describe the
roof covering and report the methods used to inspect the
roof.
5.2
The inspector is NOT required to:
A. inspect:
- antennae.
- interiors
of flues or chimneys which are not readily
accessible.
- other installed accessories.
6.
PLUMBING SYSTEM
6.1
The inspector shall:
A. inspect:
- the
interior water supply and distribution systems including
all fixtures and faucets.
- the
drain, waste and vent systems including all fixtures.
- the
water heating equipment the vent systems, flues,
and chimneys.
- the
fuel storage and fuel distribution systems.
- the
drainage sumps, sump pumps, and related piping.
B. describe:
- the
water supply, drain, waste, and vent piping materials.
- the
water heating equipment including the energy source.
- the
location of main water and main fuel shut-off valves.
6.2
The inspector is NOT required to:
A. inspect:
- the
clothes washing machine connections.
- the
interiors of flues or chimneys which are not readily
accessible.
- wells,
well pumps, or water storage related equipment.
- water
conditioning systems.
- solar
water heating systems.
- fire
and lawn sprinkler systems.
- private
waste disposal systems.
B. determine:
- whether
water supply and waste disposal systems are public
or private.
- the
quantity or quality of the water supply.
- operate
safety valves or shut off valves.
7.
ELECTRICAL SYSTEM
7.1
The inspector shall:
A. inspect:
- the
service drop.
- the
service entrance conductors, cables, and raceways.
- the
service equipment and main disconnects.
- the
service grounding. the interior components of
service panels and sub panels.
- the
conductors.
- the
over current protection devices.
- a representative
number of installed lighting
fixtures, switches, and receptacles.
- the
ground fault circuit interrupters.
B. describe:
- the
amperage and voltage rating of the service
- the
location of main disconnect(s) and sub panels
- the wiring
methods
C. report:
- on
the presence of solid conductor aluminum branch circuit
wiring
- on
the absence of smoke detectors
7.2
The inspector is NOT required to:
A. inspect:
- the
remote control devices unless the device is the only
control device.
- the alarm
systems and components.
- the
low voltage wiring, systems and components.
- the
ancillary wiring, systems and components not a
part of the primary electrical power distribution system.
- measure
amperage, voltage, or impedance.
8.
HEATING SYSTEM
8.1
The inspector shall:
A. inspect:
- the installed heating
equipment.
- the
vent systems, flues, and chimneys.
B. describe:
- the
energy source.
- the
heating method by its distinguishing characteristics.
8.2
The inspector is NOT required to:
A. inspect:
- the
interiors of flues or chimneys which are not readily
accessible.
- the
heat exchanger.
- the
humidifier or dehumidifier.
- the
electronic air filter.
- the
solar space heating system.
- determine
heat supply adequacy or distribution balance.
9.
AIR CONDITIONING SYSTEMS
9.1
The inspector shall:
A. inspect the installed central
and through-wall cooling equipment.
B. describe:
- the
energy source.
- the
cooling method by its distinguishing characteristics.
9.2
The inspector is NOT required to:
A. inspect
1. electronic
air filters.
2. determine cooling supply adequacy or distribution
balance.
10.
INTERIOR
10.1
The inspector shall:
A. inspect:
- the
walls, ceilings, and floors.
- the
steps, stairways, and railings.
- the
countertops and a representative number of installed cabinets.
- a representative
number of doors and windows.
- garage
doors and garage door operators.
10.2 The inspector is NOT required to:
A. inspect:
- the
paint, wallpaper, and other finish treatments.
- the
carpeting.
- the
window treatments.
- the
central vacuum systems.
- the household
appliances.
- recreational
facilities.
11.
INSULATION & VENTILATION
11.1
The inspector shall:
A. inspect:
- the
insulation and vapor retarders in unfinished spaces.
- the
ventilation of attics and foundation areas.
- the
mechanical ventilation systems.
B. describe:
- the
insulation and vapor retarders in unfinished spaces.
- the
absence of insulation in unfinished spaces at conditioned
surfaces.
11.2
The inspector is NOT required to:
1. disturb insulation or vapor retarders.
2.
determine
indoor air quality.
12.
FIREPLACES AND SOLID FUEL BURNING APPLIANCES
12.1
The inspector shall:
A. inspect :
- the
system components.
- the
vent systems, flues, and chimneys.
B. describe:
- the
fireplaces and solid fuel burning appliances.
- the
chimneys.
12.2
The inspector is NOT required to:
A. inspect:
- the
interiors of flues or chimneys.
- the
firescreens and doors.
- the
seals and gaskets.
- the
automatic fuel feed devices.
- the
mantles and fireplace surrounds.
- the
combustion make-up air devices.
- the
heat distribution assists whether gravity controlled
or fan assisted.
- ignite
or extinguish fires.
- determine
draft characteristics.
- move
fireplace inserts or stoves or firebox contents.
13. GENERAL LIMITATIONS AND EXCLUSIONS
13.1
General limitations:
A. Inspections
performed in accordance with these Standards of Practice
- are
not technically exhaustive.
- will
not identify concealed conditions or latent defects
These
Standards are applicable to buildings with four or less
dwelling units and their garages or carports.
13.2
General exclusions:
The inspector is
not required to perform any action or make any determination
unless specifically stated in these Standards of Practice,
except as may be required by lawful authority.
Inspectors are
NOT required to determine:
- the
condition of systems or components which
are not readily accessible.
- the
remaining life of any system or component.
- the
strength, adequacy, effectiveness, or efficiency of any system
or component.
- the
causes of any condition or deficiency.
- the
methods, materials, or costs of corrections.
- future
conditions including, but not limited to, failure of systems
and components.
- the
suitability of the property for any specialized use.
- compliance
with regulatory requirements (codes, regulations, laws,
ordinances, etc.).
- the
market value of the property or its marketability.
- the
advisability of the purchase of the property.
- the
presence of potentially hazardous plants or animals including,
but not limited to wood destroying organisms or diseases
harmful to humans.
- the
presence of any environmental hazards including, but
not limited to toxins, carcinogens, noise, and contaminants
in soil, water, and air.
- the
effectiveness of any system installed or methods
utilized to control or remove suspected hazardous substances.
- the
operating costs of systems or components.
- the
acoustical properties of any system or component.
Inspectors are
NOT required to offer:
- or
perform any act or service contrary to law.
- or
perform engineering services.
or perform work in any trade
- or
any professional service other than home
inspection.
- warranties
or guarantees of any kind.
Inspectors are
NOT required to operate:
- any system
or component which is shut
down or otherwise inoperable.
- any system
or component which does not respond to normal
operating controls.
- shut-off
valves.
Inspectors are
NOT required to enter:
- any
area which will, in the opinion of the inspector,
likely be dangerous to the inspector or other persons
or damage the property or its systems or components.
- the under-floor
crawl spaces or attics which do not conform
to recognized standards for clearance.
Inspectors are
NOT required to inspect:
- underground
items including, but not limited to underground storage
tanks or other underground indications of their presence,
whether abandoned or active.
- systems
or components which are not installed.
- decorative items.
- systems
or components located in areas which are not entered
in accordance with these Standards of Practice.
- detached
structures other than garages and carports.
- common
elements or common areas in multi-unit housing, such
as condominium properties or cooperative housing.
Inspectors are
NOT required to:
- perform
any procedure or operation which will, in the opinion
of the inspector, likely be dangerous to the inspector or
other persons or damage the property or its systems or
components.
- move
suspended ceiling tiles, personal property, furniture,
equipment, plants, soil, snow, ice, or debris.
- dismantle any
system or component, except as explicitly required by
these Standards of Practice.
GLOSSARY
GLOSSARY
of ITALICIZED WORDS*
Alarm
Systems
Warning devices, installed or free-standing, including but not limited to;
carbon monoxide detectors, flue gas and other spillage detectors, security
equipment, ejector pumps and smoke alarms
Architectural
Service
Any practice involving the art and science of building design for construction
of any structure or grouping of structures and the use of space within and
surrounding the structures or the design for construction, including but not
specifically limited to, schematic design, design development, preparation
of construction contract documents, and administration of the construction
contract
Automatic
Safety Controls
Devices designed and installed to protect systems and components from unsafe
conditions
Component
A part of a system
Decorative
Ornamental; not required for the proper operation of the essential systems
and components of a home
Describe
To report a system or component by its type or other observed, significant
characteristics to distinguish it from other systems or components
Dismantle
To take apart or remove any component, device or piece of equipment that would
not be taken apart or removed by a homeowner in the course of normal and
routine home owner maintenance
Engineering
Service
Any professional service or creative work requiring engineering education,
training, and experience and the application of special knowledge of the mathematical,
physical and engineering sciences to such professional service or creative
work as consultation, investigation, evaluation, planning, design and supervision
of construction for the purpose of assuring compliance with the specifications
and design, in conjunction with structures, buildings, machines, equipment,
works or processes
Further
Evaluation
Examination and analysis by a qualified professional, tradesman or service
technician beyond that provided by the home inspection
Home
Inspection
The process by which an inspector visually examines the readily accessible
systems and components of a home and which describes those systems and components
in accordance with these Standards of Practice
Household
Appliances
Kitchen, laundry, and similar appliances, whether installed or free-standing
Inspect
To examine readily accessible systems and components of a building in accordance
with these Standards of Practice, using normal operating controls and opening
readily openable access panels
Inspector
A person hired to examine any system or component of a building in accordance
with these Standards of Practice
Installed
Attached such that removal requires tools
Normal
Operating Controls
Devices such as thermostats, switches or valves intended to be operated by
the homeowner
Readily
Accessible
Available for visual inspection without requiring moving of personal property,
dismantling, destructive measures, or any action which will likely involve
risk to persons or property
Readily
Openable Access Panel
A panel provided for homeowner inspection and maintenance that is within normal
reach, can be removed by one person, and is not sealed in place
Recreational
Facilities
Spas, saunas, steam baths, swimming pools, exercise, entertainment, athletic,
playground or other similar equipment and associated accessories
Report
To communicate in writing
Representative
Number
One component per room for multiple similar interior components such as windows
and electric outlets; one component on each side of the building for multiple
similar exterior components
Roof
Drainage Systems
Components used to carry water off a roof and away from a building
Significantly
deficient
unsafe or not functioning
Shut
Down
A state in which a system or component cannot be operated by normal operating
controls
Solid
Fuel Burning Appliances
A hearth and fire chamber or similar prepared place in which a fire may be
built and which is built in conjunction with a chimney; or a listed assembly
of a fire chamber, its chimney and related factory-made parts designed for
unit assembly without requiring field construction
Structural
Component
A component which supports non-variable forces or weights (dead loads) and
variable forces or weights (live loads)
System
A combination of interacting or interdependent components, assembled to carry
out one or more functions
Technically
Exhaustive
An investigation that involves dismantling, the extensive use of advanced techniques,
measurements, instruments, testing, calculations, or other means
Under-floor
Crawl Space
The area within the confines of the foundation and between the ground and the
underside of the floor
Unsafe
A condition in a readily accessible, installed component or system which is
judged to be a significant risk of personal injury during normal, day-to-day
use. The risk may be due to damage, deterioration, improper installation
or a change in accepted residential construction standards.
Wiring
Methods
Identification of electrical conductors or wires by their general type, such
as "non-metallic sheathed cable" ("Romex"), "armored cable" ("bx") or "knob
and tube," etc.
*Note:
In these Standards of Practice, redundancy in the description
of the requirements, limitations and exclusions regarding the
scope of the Home Inspection is provided for clarity.
Copyright
2000 American Society of Home Inspectors, Inc. All Rights Reserved. |
|